BTU Rating12000 Btu/hr Cooling, 14000 Btu/hr Heating
Compatible Outdoor Unit ModelAC012KXADCH/AA (CXH12ADK)
Cooling at 95F: Maximum Capacity (BTUH)14500
Cooling at 95F: Minimum Capacity (BTUH)3400
Cooling at 95F: Rated Capacity (BTUH)12000
Efficiency: COP at 47F2.44
Guaranteed Operating Voltage Range (VAC)176/254 VAC
Heating at 47F: Maximum Capacity (BTUH)16200
Heating at 47F: Minimum Capacity (BTUH)3000
Heating at 47F: Rated Capacity (BTUH)14000
Indoor Unit: Drain Pipe Size Inch (mm)11/16 OD
Indoor Unit: Fan Motor FLA0.4
Indoor Unit: Fan Motor Output (W)27
Indoor Unit: Fan Motor TypeBLDC With Axial Type Fan (1)
Indoor Unit: Fan TypeBLDC with Crossflow fan (1)
Indoor Unit: Fin Gap (Inch)18
Indoor Unit: Fuse/Breaker Size (Amp)15
Indoor Unit: Heat Exchanger Tube Dia. Inch (mm)1/4
Indoor Unit: Heat Exchanger TypeAluminum Fin/Copper Tube
Indoor Unit: Refrigerant ControlEEV
Indoor Unit: Sound Pressure Level dB (A)23 / 26 / 32 / 38
Outdoor Unit: Airflow Rate (CFM)1271
Outdoor Unit: Compressor RLA8.1
Outdoor Unit: Compressor TypeInverter Driven, BLDC, Rotary
Outdoor Unit: Fan Motor FLA0.17
Outdoor Unit: Fan Motor Output (W)39
Outdoor Unit: Heat Exchanger Tube Dia. Inch (mm)3/8
Outdoor Unit: Heat Exchanger TypeAluminum, Flat Fin, Micro Channel
Outdoor Unit: Sound Pressure Level dB[A]48/48 (Cooling/Heating)
Piping: Max. Piping Height Difference Feet (m)49
Piping: Max. Piping Length Feet (m)65.6
Power Supply208/230 V/1 Phase/60 Hz
Refrigerant Data: TypeR-410A
Temperature Rating61 to 90 deg F Cooling, <=80 deg F Heating