Rheem® RHAL-FR18PJB03A Air Handler With Piston Metering, 1.5 ton, 18000 Btu/hr Cooling BTU, 600 cfm, 208/240 VAC, 60 Hz
MFG #RHAL-FR18PJB03A
Item #1049800
Mfr. Part #RHAL-FR18PJB03A
UPC #662021281839
Rheem® Air Handler, RHAL Series, RHAL-18 Model, 1.5 ton Nominal Capacity, 18000 Btu/hr Cooling BTU Rating, 208/240 VAC Voltage Rating, 10.8/12.5 A Circuit, 16/18 A Minimum Circuit, 1.5 A Motor Amperage Rating, 5.3 kW Cooling, 3 kW Heating Wattage, 1/5 hp Rating, 60 Hz Frequency Rating, 1 ph Phase, 600 cfm Rating, 13 SEER Rating, R-410A, R-22 Refrigerant Type, 20 A Fuse Rating, 20 x 20 x 1 in Filter Size, Steel, 21-1/2 in W x 17 in D x 36 in H Dimensions
Why Create an Account?
Ability to track orders
More Options & Savings
Amazing Customer Service
$1,894.52 / ea
Out of Stock
Attributes
Additional Information
Features & Benefits
Documents
Attributes
BrandRheem®
Amperage Rating10.8/12.5 A Circuit, 16/18 A Minimum Circuit, 1.5 A Motor
BTU Rating18000 Btu/hr Cooling
CFM Rating600
Dimensions21-1/2 " W x 17 " D x 36 " H
Filter Size20 x 20 x 1
Frequency Rating60
Fuse Rating20
HP Rating1/5
IndustryHVAC
MaterialSteel
ModelRHAL-18
Nominal Capacity1.5
Phase1
Refrigerant TypeR-410A, R-22
SEER Rating13
SeriesRHAL
Voltage Rating208/240
Wattage5.3 kW Cooling, 3 kW Heating
Additional Information
AHRI Certified, ISO 9001:2008, C/US UL Listed
Features & Benefits
Rugged wall steel cabinet construction, designed for added strength and versatility
1 in foil faced insulation for excellent thermal and sound performance
Four leg blower motor mount
Indoor coil design provides low air side pressure drop, high-performance and extremely compact size
Coils are constructed of aluminum fins and internally grooved copper tubing
Molded polymer corrosion resistant condensate drain pan is provided for all indoor coils
Connection point for high voltage wiring is inside the air handler cabinet, low voltage connection is made on the outside of the air handler cabinet
Concentric knockouts are provided for power connection to cabinet, Installer may pull desired hole size upto 1-3/8 in for 7/8 in conduit
PSC, two speed blower motor
20 in W x 17-7/16 in H return air opening
10 x 6 in blower
54 deg F maximum electric heat rise
Breaker disconnect configuration
Design variation
One supply circuit