Welcome to the New Keller Supply Website - Our new website is now live. Enjoy improved product search, enhanced navigation, and an upgraded online experience. We welcome your feedback as you explore the new site.
Rheem® RHBL-FR24TJB03A Air Handler With TXV Metering, 2 ton, 24000 Btu/hr Cooling BTU, 600 to 800 cfm, 208/240 VAC
MFG #RHBL-FR24TJB03A
Item #1049841
Mfr. Part #RHBL-FR24TJB03A
UPC #662021282263
Rheem® Air Handler, RHBL Series, RHBL-24 Model, 2 ton Nominal Capacity, 24000 Btu/hr Cooling BTU Rating, 208/240 VAC Voltage Rating, 10.8/12.5 A Circuit, 16/18 A Minimum Circuit, 1.5 A Motor Amperage Rating, 7.03 kW Cooling, 3 kW Heating Wattage, 1/3 hp Rating, 60 Hz Frequency Rating, 1 ph Phase, 600 to 800 cfm Rating, 14.5 SEER Rating, R-410A Refrigerant Type, 20 A Fuse Rating, 20 x 20 x 1 in Filter Size, Steel, 21-1/2 in W x 17 in D x 36 in H Dimensions
Why Create an Account?
Ability to track orders
More Options & Savings
Amazing Customer Service
$2,653.61 / ea
Out of Stock
Attributes
Additional Information
Features & Benefits
Documents
Attributes
BrandRheem®
Amperage Rating10.8/12.5 A Circuit, 16/18 A Minimum Circuit, 1.5 A Motor
BTU Rating24000 Btu/hr Cooling
CFM Rating600 to 800
Dimensions21-1/2 " W x 17 " D x 36 " H
Filter Size20 x 20 x 1
Frequency Rating60
Fuse Rating20
HP Rating1/3
IndustryHVAC
MaterialSteel
ModelRHBL-24
Nominal Capacity2
Phase1
Refrigerant TypeR-410A
SEER Rating14.5
SeriesRHBL
Voltage Rating208/240
Wattage7.03 kW Cooling, 3 kW Heating
Additional Information
AHRI Certified, ISO 9001:2008, C/US UL Listed
Features & Benefits
Rugged wall steel cabinet construction, designed for added strength and versatility
1 in foil faced insulation for excellent thermal and sound performance
Four leg blower motor mount
Indoor coil design provides low air side pressure drop, high-performance and extremely compact size
Coils are constructed of aluminum fins and internally grooved copper tubing
Molded polymer corrosion resistant condensate drain pan is provided for all indoor coils
Connection point for high voltage wiring is inside the air handler cabinet, low voltage connection is made on the outside of the air handler cabinet
Concentric knockouts are provided for power connection to cabinet, Installer may pull desired hole size upto 1-3/8 in for 7/8 in conduit
X-13(ECM), two speed blower motor
20 in W x 17-7/16 in H return air opening
10 x 6 in blower
44 deg F maximum electric heat rise
Breaker disconnect configuration
Design variation
One supply circuit