Samsung MWR-SH11UN Simple Touch Controller, Outputs: 16, 328 ft L Cable
MFG #MWR-SH11UN
Item #1064066
Mfr. Part #MWR-SH11UN
UPC #
Samsung Simple Touch Controller, 12 V, 16 Outputs, 328 ft Cable Length, 3-11/16 in Overall Length, 4-13/16 in Overall Width, 3/4 in Overall Depth, For Use With: Samsung NASA DVM S, CAC, RAC and FJM Indoor Units Only
Why Create an Account?
Ability to track orders
More Options & Savings
Amazing Customer Service
$415.80Â /Â ea
In Stock
Attributes
Features & Benefits
Documents
Attributes
BrandSamsung
Cable Length328
IndustryHVAC
Outputs16
Overall Depth3/4
Overall Length3-11/16
Overall Width4-13/16
Suitable For Use WithSamsung NASA DVM S, CAC, RAC and FJM Indoor Units Only
Voltage Rating12
Features & Benefits
Internal temperature sensor
Backlight display
Built-in infrared receiver to allow control of indoor unit wirelessly with AREH03U, AR-EH04U, AR-KH03U or AR-KH04U wireless controllers
Indoor unit operation on-off, operation mode, set temperature, louver position (cassette, ceiling, wall units) and fan speed settings
Error display
Filter replacement alarm display and reset
Single indoor unit control or multiple unit control (maximum 16-units)
Partial controller button lock (on-off, temperature setting, fan speed, timer function, louver swing, sleep function, quiet function, outing function and operation mode buttons)
Upper and lower temperature setting restriction
Heat, cool, dry, fan and auto mode skip options (skips specified mode on wired controller)
Single event timer function (on-off control, 30 min to 24 hr timer setting options)
System/indoor unit function and operation indication (defrost, error, restricted controller, central control and SPI status)
Service mode for connected indoor unit operation monitoring, addressing and setup
Can be used to specify mode master while connected to a single indoor unit when used with heat pump systems to control system mode (heating or cooling)
Outing function to keep a minimum heating (61 to 72 deg F) and cooling (77 to 86 deg F) temperature while you are away
When outing mode is activated, the unit will operate at the specified outing temperature
If indoor temperature is 9 deg F difference from desired outing temperature, the indoor unit will turn on
If indoor temperature is the same as desired outing temperature, the indoor unit will turn off automatically
This is repeated depending on indoor temperature for 12 hr
After 12 hr, outing mode is released/canceled