Welcome to the New Keller Supply Website - Our new website is now live. Enjoy improved product search, enhanced navigation, and an upgraded online experience. We welcome your feedback as you explore the new site.
Rheem® RAWL-121CAZ Condensing Unit, 10 ton, 208-230 V, 113000 Btu/hr
MFG #RAWL-121CAZ
Item #1168421
Mfr. Part #RAWL-121CAZ
UPC #66202146687
Rheem® Condensing Unit, RAWL Series, 121CAZ Model, 10 ton Nominal Capacity, 113000 Btu/hr BTU Rating, 208-230 V Voltage Rating, 48 A Amperage Rating, 35.2 kW Wattage, 1075 rpm Rotational Speed, 60 Hz Frequency Rating, 3 ph Phase, 8000 cfm Rating, 11.2 EER Rating, R-410A Refrigerant Type, 88 dBA Sound Level, 32.88 sq-ft Face Area, Steel, Galvanized/Powder-Coated, 44-3/4 in H x 72-3/8 in W x 38-3/8 in D Dimensions
Why Create an Account?
Ability to track orders
More Options & Savings
Amazing Customer Service
$15,953.70 / ea
Out of Stock
Attributes
Additional Information
Features & Benefits
Documents
Attributes
BrandRheem®
Amperage Rating48
BTU Rating113000
CFM Rating8000
Dimensions44-3/4 " H x 72-3/8 " W x 38-3/8 " D
EER Rating11.2
Face Area32.88
FinishGalvanized/Powder-Coated
Frequency Rating60
IndustryHVAC
MaterialSteel
Model121CAZ
Nominal Capacity10
Phase3
Refrigerant TypeR-410A
Rotational Speed1075
SeriesRAWL Series
Sound Level88
Voltage Rating208-230
Wattage35.2
Additional Information
AHRI Certified|C/US UL Listed
Features & Benefits
Cabinet, galvanized steel with a durable powder paint finish, stamped louvered panels offer 100% protection for the condenser coil
Scroll compressor is hermetically sealed with internal high-temperature protection and durable insulation on motor windings, the entire compressor is mounted on rubber grommets to reduce vibration and noise
Condenser coil is constructed with copper tubes and aluminum fins mechanically bonded to the tubes for maximum heat transfer capabilities
Base pan, galvanized steel with powder paint finish
Refrigerant connections-field piping connections are made through a fixed panel, this allows removal of access panels after piping connections have been made
Crankcase heaters standard, all models, prevents refrigerant migration to compressors
Low ambient control-a pressure sensitive fan cycling control allows operation of units down to 0 deg F
Service valves standard on liquid and suction lines, allows outdoor section to be isolated from indoor coil
Service access control box as well as the compressor and other refrigerant controls are accessible through access panels, control box may be open without affecting the normal operation of the unit, condenser fan motors are accessible by removing wire grilles
Filter drier standard (uninstalled) on all models, helps ensure refrigerant cleanliness
Transformer step down type, line to 24 V, provides control circuit voltage
Contactor is an electrical switch which operates the compressor and condenser fans
High-pressure control-opens the contactor circuit on high-refrigerant pressure, manual reset
low-pressure control stops compressor operation in the event of loss of refrigerant
Condenser fan motor direct drive ball bearing 1075 rpm motors are mounted to minimize vibration and noise problems, these are permanent split capacitor types
Testing all units are run tested at the factory prior to shipment, units are shipped with a holding charge of nitrogen
External gauge ports allows pressures to be checked without removing access panel
Coil louvers helps prevent damage to outdoor coils
Time delay, supplied on tandem compressor model to provide a delay between stages
Equipment ground lug for field connection of ground wire