Welcome to the New Keller Supply Website - Our new website is now live. Enjoy improved product search, enhanced navigation, and an upgraded online experience. We welcome your feedback as you explore the new site.
Samsung AC042BXADCH/AA Duct Split System Outdoor Unit, 208-230 V, 32.2 A, 12000 to 46000 Btu/hr Cooling, 1 ph Phase
MFG #AC042BXADCH/AA
Item #1230182
Mfr. Part #AC042BXADCH/AA
UPC #88727657734
Samsung Duct Split System Outdoor Unit, 208-230 V, 32.2 A, 60 Hz, 1 ph Phase, 2 Fan Speeds, 11000 to 63000 Btu/hr Heating, 12000 to 46000 Btu/hr Cooling, 1236 cfm Heating CFM Rating, 1236 cfm Cooling CFM Rating, 9.2 EER Rating, 17.5, 18.1 SEER, 8.8, 8.4 HSPF, 3/8 in Liquid Line, 5/8 in Suction Line, 55 dBA Heating Sound Level, 53 dBA Cooling Sound Level, Steel, Finish: Galvanized, -4 to 75 deg F Heating Operating Temperature, 23 to 122 deg F Cooling Operating Temperature, 37 in Overall Width, 47-11/16 in Overall Height, Additional Information: Single-Zone, 13 in D Dimensions
Why Create an Account?
Ability to track orders
More Options & Savings
Amazing Customer Service
$6,275.88 / ea
Out of Stock
Attributes
Additional Information
Features & Benefits
Documents
Marketing Information
Attributes
BrandSamsung
Additional InformationSingle-Zone, 13 " D Dimensions
Amperage Rating32.2
Cooling BTU Rating12000 to 46000
Cooling CFM Rating1236
Cooling Operating Temperature23 to 122
Cooling Sound Level53
EER Rating9.2
FinishGalvanized
Frequency Rating60
Heating BTU Rating11000 to 63000
Heating CFM Rating1236
Heating Operating Temperature-4 to 75
Heating Sound Level55
HSPF Rating8.8, 8.4
Liquid Line Size3/8
MaterialSteel
Number of Fan Speeds2
Overall Height47-11/16
Overall Width37
Phase1
SEER Rating17.5, 18.1
Suction Line Size5/8
Voltage Rating208-230
Warranty10 Year Compressor, 10 Year Parts, 1 Year Limited Labor
Additional Information
AHRI 210/240/2017/2023|cCSAus Certified|ENERGY STAR Certified
Features & Benefits
The outdoor unit shall supply power to indoor unit via 14 AWG x 3 power wire
High voltage terminal block temperature sensor to disable unit in the event of power connection overheating
Integral condensate pump with maximum 29 in lift from bottom of the unit with check valve and float switch that disables indoor should condensate overflow be detected
Auto restart after power loss
Soft-start compressor minimizing current inrush
All heat exchangers shall be mechanically bonded aluminum fin to copper tube
The compressor shall be hermetically sealed, inverter-controlled BLDC rotary-type
Refrigerant flow shall be controlled by an electronic expansion valve at outdoor unit
Air filtration shall be field provided
Pressure drop across field-supplied filter must be factored into the total ESP
Outdoor unit for CAC slim duct, duct S, WindFree™ four way cassette, WindFree™ mini four way cassette, WindFree™ one way cassette, 360 cassette, multi-position air handler, console and high wall units.
Samsung AC042BXADCH/AA Duct Split System Outdoor Unit, 208-230 V, 32.2 A, 12000 to 46000 Btu/hr Cooling, 1 ph Phase