Welcome to the New Keller Supply Website - Â Our new website is now live. Enjoy improved product search, enhanced navigation, and an upgraded online experience. We welcome your feedback as you explore the new site.
Samsung AC036BNZDCH/AA Split System Air Handling Unit, 36000 Btu/hr Cooling, 1229 cfm, 208 to 230 V, 24.5 A, 410 W
MFG #AC036BNZDCH/AA
Item #1286083
Mfr. Part #AC036BNZDCH/AA
UPC #88727657726
Samsung Split System Air Handling Unit, FJM Series, 36000 Btu/hr Cooling Capacity, 36000 Btu/hr Heating Capacity, 208 to 230 V Voltage Rating, 24.5 A Amperage Rating, 410 W Wattage, 60 Hz Frequency Rating, 1 ph Phase, 1229 cfm Rating, Multi-Position Configuration, 9.6 EER Rating, 16.6 SEER Rating, R-410A Refrigerant Type, 54 dBA Sound Level, 3/4 in Connection, 3/8 in Liquid Line Size, 5/8 in Suction Line Size, 3 Number of Speeds, ECM Constant Torque Motor Type, 1 in-WC, Steel, Galvanized, 70 to 80 deg F Temperature Rating, 47-11/16 in H x 37 in W x 13 in D Dimensions, Electronic Expansion Valve Control Unit, Single Zone Duct Additional Information
Why Create an Account?
Ability to track orders
More Options & Savings
Amazing Customer Service
$4,965.84Â /Â ea
In Stock
Attributes
Additional Information
Features & Benefits
Documents
Marketing Information
Attributes
BrandSamsung
Additional InformationElectronic Expansion Valve Control Unit, Single Zone Duct
Amperage Rating24.5
CFM Rating1229
ConfigurationMulti-Position
Connection Size3/4
Cooling Capacity36000
Dimensions47-11/16 " H x 37 " W x 13 " D
EER Rating9.6
FinishGalvanized
Frequency Rating60
Heating Capacity36000
IndustryHVAC
Liquid Line Size3/8
MaterialSteel
Motor TypeECM Constant Torque
Number of Speeds3
Phase1
Pressure Rating1
Refrigerant TypeR-410A
SEER Rating16.6
SeriesFJM Series
Sound Level54
Suction Line Size5/8
Temperature Rating70 to 80
Voltage Rating208 to 230
Wattage410
Additional Information
cETLus Listed|UL 1995
Features & Benefits
High voltage terminal block temperature sensor to disable unit in the event overheating of power connection
Auto restart after power loss
Soft start compressor minimizing current inrush
All heat exchangers shall be mechanically bonded aluminum fin to copper tube
The condensing unit heat exchanger salt spray test method ISO 9227 the heat exchanger showed no unusual rust or corrosion development to 3000 hr
Highly adaptable, the multi-position air handler (MPAH) can be installed in numerous positions for added installation flexibility. With the ability to handle the external static pressure up to 0.8 in-WC, the MPAH provides expansive coverage with outstanding cooling and heating performance.
Samsung AC036BNZDCH/AA Split System Air Handling Unit, 36000 Btu/hr Cooling, 1229 cfm, 208 to 230 V, 24.5 A, 410 W