Welcome to the New Keller Supply Website - Our new website is now live. Enjoy improved product search, enhanced navigation, and an upgraded online experience. We welcome your feedback as you explore the new site.
Rheem® Eclipse Series RPCL2090CBZ Commercial Split Compressor Heat Pump Condenser, 7.5 ton, 85000 Btu/hr BTU, 208/230 V
MFG #RPCL2090CBZ
Item #1361231
Mfr. Part #RPCL2090CBZ
UPC #66202163524
Rheem® Commercial Split Compressor Heat Pump Condenser, Achiever® Series, 208/230 V Voltage Rating, 39 A Amperage Rating, 24.9 kW Power Rating, 60 Hz Frequency Rating, 3 ph Phase, 85000 Btu/hr BTU Rating, 5000 cfm Rating, 11 EER Rating, 14.1 SEER Rating, Scroll Compressor Type, R-410A Refrigerant Type, 1/2 in Liquid Line Size, 1-1/8 in Suction Line Size, 7.5 ton Tonnage, 2 Number of Stages, Steel, Baked Enamel, 42-11/16 in L x 31-1/8 in W x 48-13/16 Dimensions
Why Create an Account?
Ability to track orders
More Options & Savings
Amazing Customer Service
$12,260.61 / ea
Out of Stock
Attributes
Additional Information
Features & Benefits
Documents
Attributes
BrandRheem®
Amperage Rating39
BTU Rating85000
CFM Rating5000
Compressor TypeScroll
Dimensions42-11/16 " L x 31-1/8 " W x 48-13/16
EER Rating11
FinishBaked Enamel
Frequency Rating60
IndustryHVAC
Liquid Line Size1/2
MaterialSteel
Number of Stages2
Phase3
Power Rating24.9
Refrigerant TypeR-410A
SEER Rating14.1
SeriesACHIEVER Series
Suction Line Size1-1/8
Tonnage7.5
Voltage Rating208/230
Additional Information
AHRI Certified|cULus Listed|DOE 2023
Features & Benefits
All access panels can be opened or removed without affecting the structural strength of the unit stamped louvered panels offer 100% protection for the condenser coil
Lug for field connection of ground wire
The contactor is an electrical switch which operates the compressor and outdoor fans Its 24 V coil is activated on a call for cooling or heating
75 VA step down-type, from Line to 24 V with resettable circuit breaker
Help provide starting torque necessary to boost the condenser fan motors to operating speed by directing their stored energy to the starter winding in step with the running winding
Used when unit is in heating mode to defrost outdoor coil
To provide compressor protection under abnormally high head pressure conditions (outdoor fan failure, restriction, dirty coil and more) or abnormally low suction pressure conditions (restrictions, TEV failure, loss of charge, indoor blower failure and more) while eliminating nuisance tripping sometimes experienced with conventional control systems
Constructed with copper tubes and aluminum fins mechanically bonded to tubes for maximum heat transfer capabilities, all coil assemblies are leak tested up to 550 psig internal pressure
Control box with separate line and control voltages, as well as compressor and other refrigerant controls are accessible through access panels, an electrical access cover may be opened or removed without affecting normal operation of the unit, condenser fan motors are equipped with molded plugs for easy removal, Louver panels and end access panel can be removed for coil cleaning
Galvanized steel with weather-resistant baked enamel finish
The scroll compressor is hermetically sealed with internal high temperature protection and durable insulation on motor windings, the entire compressor is mounted on rubber grommets to reduce vibration and noise
Used when unit is in heating mode and outdoor coil functions as evaporator
Minimizes refrigerant migration to compressor sump
To prevent liquid slugging of compressor
All field sweat joints are made external of the unit and are located close to the ground for a neat looking installation
Standard on liquid line and vapor line
Sized for maximum capacity and efficiency, 24 V coil, energized in heating