Welcome to the New Keller Supply Website - Our new website is now live. Enjoy improved product search, enhanced navigation, and an upgraded online experience. We welcome your feedback as you explore the new site.
Rheem® Endeavor® Cased Coil, RCFY Series, NPT Connection, 48000 Btu/hr, 600 to 1900 cfm, Gas, Oil Fuel, For Use With: Gas and Oil Furnaces, Aluminum, 28 in H x 21 in W x 21-11/16 in D, Additional Information: Standard Efficiency, TXV Metering Device, Multi-Poise Orientation, R-454B Refrigerant-Type, 2-Row 8.55 sq-ft Face Area Coil Rating
Why Create an Account?
Ability to track orders
More Options & Savings
Amazing Customer Service
$2,792.13 / ea
In Stock
Attributes
Additional Information
Features & Benefits
Documents
Marketing Information
Attributes
BrandRheem®
Additional InformationStandard Efficiency, TXV Metering Device, Multi-Poise Orientation, R-454B Refrigerant-Type, 2-Row 8.55 sq-' Face Area Coil Rating
BTU Rating48000
CFM Rating600 to 1900
Coil SeriesN-Coil
Connection TypeNPT
Dimensions28 " H x 21 " W x 21-11/16 " D
Fuel TypeGas, Oil
MaterialAluminium
Nominal Capacity48000 Btu/hr
SeriesRCFY Series
Suitable For Use WithGas and Oil Furnaces
Warranty10 Year Limited Conditional Parts
Additional Information
AHRI Certified
Features & Benefits
Rheem® Indoor Furnace cased coils and replacement uncased coils are designed for use with Rheem outdoor units and are available for vertical upflow or downflow, and horizontal left or horizontal right airflow. When matched with Rheem outdoor units, the coils provide a nominal capacity range from 18,000 BTU/HR [5.24 kW] to 60,000 BTU/HR [17.6 kW]
Constructed of aluminum fins bonded to internally grooved aluminum tubing
Coils are tested at the factory with an extensive refrigerant leak check
Coils have copper sweat refrigerant connections
Feature two sets of 3/4" [19.1 mm] N.P.T. Condensate drain connections for ease of connection
Chatleff metering device connections, at inlet and outlet of TXV or EXV and equalizer connections (TXV only)
Approved for system application with variety of Rheem outdoor units
Condensate drain pan is constructed of high grade, heat resistant, corrosion free thermal-set material
Compatible with Germicidal Light System (UV resistant)
Bi-Directional airflow eliminates the need to switch any internal components from horizontal left to right
Unique drain pan design maximizes application flexibility and condensate removal
N-Coil design maximizes performance and minimizes height required at installation
Coils are AHRI certified for system application with a variety of Rheem outdoor units
Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78%1 lower GWP than previous-generation refrigerants - with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort
PlusOne® Refrigerant Detection System™2: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation - if excess refrigerant is detected
Rheem® Endeavor® Cased Coil, RCFY Series, NPT Connection, 48000 Btu/hr, 600 to 1900 cfm, Gas, Oil Fuel, For Use With: Gas and Oil Furnaces, Aluminum, 28 in H x 21 in W x 21-11/16 in D, Additional Information: Standard Efficiency, TXV Metering Device, Multi-Poise Orientation, R-454B Refrigerant-Type, 2-Row 8.55 sq-ft Face Area Coil Rating