RUUD® Endeavor RCFY Series TXV RCFY4824MTANMC Line Cased Furnace Coil, 3/4 in, 48000 Btu/hr BTU, NPT, Aluminum
MFG #RCFY4824MTANMC
Item #1408634
Mfr. Part #RCFY4824MTANMC
UPC #662021710117
RUUD® Endeavor Line Cased Furnace Coil, RCFY Series, Model: TXV, 3/4 in, NPT Connection, 48000 Btu/hr, 600 to 1900 cfm, Aluminum, 24-1/2 in W x 19-7/8 in D
Why Create an Account?
Ability to track orders
More Options & Savings
Amazing Customer Service
$3,908.30 / ea
In Stock
Attributes
Additional Information
Features & Benefits
Documents
Marketing Information
Attributes
BrandRheem®
BTU Rating48000
CFM Rating600 to 1900
Connection TypeNPT
Dimensions24-1/2 " W x 19-7/8 " D
Flow Rate600 cfm, 900 cfm cfm
Fuel TypeGas, Oil
IndustryHVAC
MaterialAluminum
ModelTXV
SeriesRCFY Series
Size3/4
Suitable For Use WithGas and Oil Furnaces
Warranty10 Year Limited Conditional Parts
Additional Information
AHRI Certified
Features & Benefits
Ruud® Indoor Furnace cased coils and replacement uncased coils are designed for use with Ruud outdoor units and are available for vertical upflow or downflow, and horizontal left or horizontal right airflow. When matched with Ruud outdoor units, the coils provide a nominal capacity range from 18,000 BTU/HR [5.24 kW] to 60,000 BTU/HR [17.6 kW].
Constructed of aluminum fins bonded to internally grooved aluminum tubing.
Coils are tested at the factory with an extensive refrigerant leak check.
Coils have copper sweat refrigerant connections.
Feature two sets of 3/4" [14.1 mm] N.P.T. Condensate drain connections for ease of connection.
Chatleff metering device connections, at inlet and outlet of TXV or EEV and equalizer connections (TXV only).
Approved for system application with variety of Rheem outdoor units.
Condensate drain pan is constructed of high grade, heat resistant, corrosion free thermal-set material.
Compatible with Germicidal Light System (UV resistant)
Bi-Directional airflow eliminates the need to switch any internal components from horizontal left to right.
Unique drain pan design maximizes application flexibility and condensate removal.
N-Coil design maximizes performance and minimizes height required at installation.
Coils are AHRI certified for system application with a variety of Rheem outdoor units.
Rheem® Endeavor® Line Cased Furnace Coil, RCFY Series, NPT Connection, 600 cfm, 900 cfm Flow Rate, 48000 Btu/hr, Gas, Oil Fuel, For Use With: Gas and Oil Furnaces, Aluminum, 32 in H x 24-1/2 in W x 21-11/16 in D, Additional Information: Medium Efficiency, 9.98 sq-ft Face Area, 13 FPI, 3-Row, R-454B Refrigerant, Multi-Poise Orientation