Samsung AC048JN4DCH/AA Mini-Split Heat Pump, 208 to 230 V, 22.2 A, 48000 Btu/hr Btu, 1 ph, Steel
MFG #AC048JN4DCH/AA
Item #956309
Mfr. Part #AC048JN4DCH/AA
UPC #
Samsung Mini-Split Heat Pump, 208 to 230 V, 22.2 A, 97 W, 125 W, 60 Hz, 1 ph, 48000 Btu/hr, 1300 cfm, 3040 cfm Rating, 9.7 EER, 18.8 SEER, HSPF: 9.5, Flared Connection Type, Rotary Compressor, R-410A, 4 ton Tonnage, 45 dBA, Cassette Mount, Steel, Galvanized, 61 to 90 deg F, 33 in Overall Width, 11-5/16 in Overall Height, Additional Information: 14.8 pt/hr Dehumidification, 18 FPI Fins per Inch, 33 in D
Why Create an Account?
Ability to track orders
More Options & Savings
Amazing Customer Service
$1,839.24Â /Â ea
Out of Stock
Attributes
Additional Information
Features & Benefits
Documents
Attributes
BrandSamsung
Additional Information14.8 pt/hr Dehumidification, 18 FPI Fins per ", 33 " D
Amperage Rating22.2
BTU Rating48000
CFM Rating1300 cfm, 3040 cfm
Compressor TypeRotary
Connection TypeFlared
Dehumidification14.8 pt/hr
Dimensions11-5/16" H x 33" W x 33" D
EER Rating9.7
FinishGalvanized
Fins per Inch18 FPI
Frequency Rating60
HSPF Rating9.5
MaterialSteel
Mounting TypeCassette
Overall Height11-5/16
Overall Width33
Phase1
Power Rating97 W, 125 W
Refrigerant TypeR-410A
SEER Rating18.8
Sound Level45
Temperature Rating61 to 90
Tonnage4
Voltage Rating208 to 230
Additional Information
cETLus Intertek Listed
Features & Benefits
Low ambient control
Auto restart after power loss
The indoor and outdoor units shall have a removable EEPROM that stores system programming information, unit name and other data
Electro-static, washable, pleated filter as standard (included with fascia panel)
Built-in condensate pump and check valve with maximum 29 in lift
Knock-out for outside air capability (with booster fan connection)
Fascia panel shall have LED indicator lights, IR receiver and four motorized louvers (independent louver control is possible with wireless or premium wired controller)
Pipe connections at the outdoor unit shall be made inside the unit chassis, refrigerant pipes can exit through the front, side, rear or bottom sides of the outdoor unit
The indoor unit shall be have a galvanized steel frame with HIPS chassis and fascia panel certified to UL94 V0
The indoor unit heat exchanger shall be mechanically bonded fin to copper tube
Control signal shall be a DDC-type signal
Interconnect control wire between outdoor and indoor units shall be 16 AWG x two-shielded
Controls shall integrate with a BMS system
The system shall integrate with the Samsung NASA controls solution
The compressor shall be hermetically sealed, inverter controlled, BLDC rotary
Refrigerant flow shall be controlled by electronic expansion valve at outdoor unit
Soft start to reduce current demand during compressor start
10 years compressor and parts warranty