Welcome to the New Keller Supply Website - Â Our new website is now live. Enjoy improved product search, enhanced navigation, and an upgraded online experience. We welcome your feedback as you explore the new site.
Samsung AC024MXSCCC/AA Low Ambient Cooling Outdoor Unit, 208-230 V, 16 A, 1 ph
MFG #AC024MXSCCC/AA
Item #978994
Mfr. Part #AC024MXSCCC/AA
UPC #
Samsung Low Ambient Cooling Outdoor Unit, 208-230 V, 16 A, 60 Hz, 1 ph, 24000 Btu/hr Heating, 551 cfm Heating CFM Rating, 10.55 EER Rating, 18.3 SEER, 20 A Fuse Rating, 50 dBA Heating Sound Level, Wall Mounting, 23 to 115 deg F Heating Operating Temperature, 34-5/8 in Overall Length, 12-3/16 in Overall Width, 31-7/16 in Overall Height
Why Create an Account?
Ability to track orders
More Options & Savings
Amazing Customer Service
$3,194.64Â /Â ea
Out of Stock
Attributes
Additional Information
Features & Benefits
Documents
Attributes
BrandSamsung
Amperage Rating16
EER Rating10.55
Frequency Rating60
Fuse Rating20
Heating BTU Rating24000
Heating CFM Rating551
Heating Operating Temperature23 to 115
Heating Sound Level50
IndustryHVAC
Model NumberAC0
Mounting TypeWall
Overall Height31-7/16
Overall Length34-5/8
Overall Width12-3/16
Phase1
SEER Rating18.3
Voltage Rating208-230
Additional Information
AHRI 10491545|cETLus Intertek Listed|UL 1995
Features & Benefits
Wall-mounted evaporator
Low ambient cooling to -40 deg
The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire
Auto-restart after power loss
The outdoor unit shall have a snow accumulation prevention option setting to prevent snow drifting against an idle outdoor unit.
The indoor unit shall have a removable EEPROM that stores system programming information, unit name, and other data
The outdoor unit shall have a night time quiet mode option to reduce operating sound during the night.
Construction - The outdoor unit shall be galvanized steel with a baked on powder coated finish for durability
Indoor unit chassis shalle be UL94 V0 with a galvanized steel mounting plate
The indoor unit shall have easy-access to wire, pipe, and drain connections via access panel on front of unit for easier installation and service
The indoor unit and outdoor unit heat exchangers shall be mechanically bonded aluminum fin to copper tube
Control signal shall be a DDC type signal
Advanced configuration options for high room temperature alerts using MIM-B14 external contact control to enable a backup system and/or to notify a BMS (refer to technical documents available at www.DVMdownload.com for full details).
Interconnect control wire between outdoor and indoor unit shall be 16AWG X 2 shielded
Wired controllers must be purchased separately
Wireless controller included
Controls shall integrate with a BMS system
The system shall integrate with the Samsung NASA Controls Solution